Syringe Pump

Numeric Keypad

More Syringe Mode Optional˙Accurate Injection

Syringe Pump Features

The Syringe Pump is with the classic double channel design. It is open system and can accept different syringe brand after calibration. The software compensation error is within±2% after calibration. It is widely used in ICU, NICU, pediatrics, internal medicine, surgery, obstetrics and gynecology, oncology, emergency department and outpatient infusion room. Double CPU and numeric keypad make it more user friendly.

·Friendly UI Interface

Like ATM interface

·Strong Battery Backup

3000mAh battery and backup time more than 6hrs.

·Adjustable Level

Occlusion,alarm volume,brightness adjustable 

·Injection Mode

Constant rate,volume/time,drug mode,micro-mode, programmable mode,etc.

·Event Log

More than 10000 logs

Product parameters

HF-620B SYRINGE PUMP -DOUBLE CHANNEL

Specification

Injection Mode

Constant rate,time/volume mode,drug weight mode,micro-mode,programmable mode,druglibrary mode

Syringe Size

5ml10ml20ml30ml50/60ml,auto-recognition

Flow Rate

5ml:0.10ml/h-60.00ml/h 10ml:0.10ml/h-300.00ml/h
20ml:0.10ml/h-400.00ml/h 30ml:0.10ml/h-600.00ml/h
50/60ml:0.10ml/h-1200.00ml/h

Increment

0.01ml/h

Preset Time

1s99hr59min59s

Parameter Changed during Injection

Support change of VTBI,flow rate during injection

Accuracy

≤±2%(±1%mechanical accuracy included)

Preset Volume (VTBI)

0.10-9999.99ml&empty

Accumulated Volume

0.00-9999.99ml

Purge Rate

5ml:30.00-60.00ml/h 10ml:150.00-300.00ml/h
20ml:200.00-400.00ml/h;30ml:300.00-600.00ml/h
50ml:600.00-1200.00ml/h

Bolus Rate

5ml:0.10ml/h-60.00ml/h 10ml:0.10ml/h-300.00ml/h
20ml:0.10ml/h-400.00ml/h 30ml:0.10ml/h-600.00ml/h
50/60ml:0.10ml/h-1200.00ml/h

KVO

0.10-5.00ml/h adjustable

Occlusion Pressure

8 level adjustable,20Kpa-150Kpa,dynamically pressure value display.

Alarm

Finished,near finished,near empty,empty,occlusion,syringe disconnected,no operation,parameter error,syringe error,low battery,battery lost,battery ran out,AC power lost,abnormal injection,communication error,finished!KVO.

Syringe Management

Preset 20 syringe brands,can add or edit the brand,accept different brands after calibration

Display

5.0’TFT colorLCD,10 level brightness adjustable

Pressure Release Function

Pressure release function after occlusion

Power Supply

AC Power:100V-240V,50/60Hz,≤45W

Battery

Rechargeable Lithium battery,DC11.1V,3000mAh;
operating time:≥6h @5ml/h

Alarm Voice

Standard Medical Alarm Voice with mute function,8 levels  adjustable.

Event Log

10000 logs

Operation
Environment

+5-+40,Relative humidity:20%-90%;Atmospheric
pressure:70-106 Kpa

Classification

ClassII,Type CF;IPX4

Dimension

Size:290mm×150 mm×224mm,Weight:3.5kg

Other Function

Double CPU,Password function,90 ⁰ratable IV pole,4 soft function key:key lock function,numeric keypad,sleeping function

Application

Intravenous injection

Online
Message


If you have any suggestions or feedback on our company, please fill in the relevant information on this page and submit it. A staff member will contact you in time, or please call us directly.

Phone

Inquiry